OTM2540 43G OTN Transport Test Module

OTM2540 43G OTN Transport Test Module
Product Detailed
Round-trip delay measurements Independent transmitter and receiver testing Senior through mode measurement

Description 

OTM2540 43G OTN transport test module is one of OPWILL’s modular test products. OTM2540 can be configured on OTP6800 test platforms to achieve TN test functionalities and offer comprehensive test solutions for metro network. It is a high cost-effective network test product.

Highlights

Offer 43GSDH/SONET/OTN test functionsFEC capability analysis and ODU multiplex test of OTU3 optical signal as per ITU-T G.709Automatic signal structure discovery in smartmode, automatically detect and monitor error pathsIntuitionistic user interface, fast configuration of signal pathsCustomizable various forms of test report

  Applications

OTN testing at the OTU3 level including FEC as per ITU-T G.709

Support OTU3 (43Gbit/s) optical interface relative testBERT and FEC analysis of OTU3 according to ITU-T G.709 frames2.5G/10G SDH/SONET signal synchronous/asynchronous mapping and demapping in OTNRound-trip delay measurementsIndependent transmitter and receiver testingOTN alarm generation and monitoringOTN overhead manipulation and captureFrequency analysis and power measurementFrequency offset generationAutomatic protection switching and service disruption time measurementsSenior through mode measurement

OTM2540 OTN Series Specifications

Test Interfaces 

OTU3(43G) optical interface

BNC DS1/E1/2MHz outside clock interface

Test Features

OTN

Payloads

Support mapping/demapping from AU-3/AU-4/AU-4-4c/AU-4-16c to OTU1

Support mapping/demapping from AU-3/AU-4/AU-4-4c/AU-4-16c/AU-4-64c to OTU2

Support multiplexing/demultiplexing from ODU0,ODU1,ODU2,ODUflex to ODU3

Test patterns

PBBS

2E23,2E31

Fixed

All 1s,All 0s

User programmable

Allowing user define 8-byte test pattern

Error injection

FAS,BIP-8(SM, PM, TCM1-6),BEI(SM, PM, TCM1-6), Bit,FECcorrectable bit, FECcorrectable code word, FECuncorrectable  code word,Fec correctable Symbol

Alarm generation

OTU:LOF,OOF ,LOM,  OOM,AIS,SM-BDI,SM-IAE,SM-TIM,SM-BIAE

ODU:ODTU-LOFLOM,ODU-AIS,ODU-OCI,ODU-LCK,ODU-BDI,ODU-TIM,ODU-FSF,ODU-BSF,ODU-FSD,ODU-BSD

ODU-TCM1~6:BDI,IAE,TIM,LTC,BIAE

OPU:OPU-PLM,OPU-CSF,OPU-MSIM,CLIENT-LSS

Test result

Error

FAS,BIP-8(SM, PM, TCM1-6),BEI(SM, PM, TCM1-6), Bit,FECcorrectable bit, FECcorrectable code word, FECuncorrectable  code word

Alarm

OTU:LOF,OOF,LOM,  OOM ,AIS,SM-BDI,SM-IAE,SM-TIM,SM-BIAE

ODU:AIS,ODU-OCI,ODU-LCK

TCM1~6:BDI,IAE,TIM,LTC,BIAE

PM:BDI,TIM

Overhead features

Manipulation and capture

 

Overhead setting: all bytes are editable, not including MFAS, SM BIP, PM BIP, TCM1-6 BIP

Continuous and variable capture ability

Display integrated overhead

Protection switching time

Term of service disruption

Alarm: LOS, LOM, OOM, SM-IAE,  SM-BIAE, ODU-AIS, ODU-OCI, ODU-LCK, PM-BDI;

Error: MFAS, PM-BIP, PM-BEI, payload errors

Delay

Time test precision 0.1ms

Other Test and Measurement Functions

Power measurement

Support power measurement of optical interface(dBm). Precision:0.1dBm. Range:-40~+8.2dBm

Frequency measurement

Support clock frequency measurement of optical interface(measure received frequency of input signal and deviation with rating frequency), display in b/s(bps) and ppm. PrecisionL 1b/s and 1 ppm

Frequency offset generation

Support to offset signal transmission clock in selected interface, and recover the circuit through tested network clock. Generation range:-100ppm~+100ppm

Loop-back delay measurement

Measure the time of one overhead sending from OTM2540 TX and loop-back then back to RX. Suitable for all interfaces and mapping. MeasurementL final RTD time, minimum calue, maximum value, average value, measured count(successful TRD measurement number), loss measurement count.

Through mode

Support OTU3 high level through mode

Path scan

Automatically scan pointed signal structure path

OTM2540 43G OTN Transport Test Module